Analysis of the Wastewater Treatment System at Dompu Regional General Hospital, West Nusa Tenggara

Authors

  • Muhamad Yamin Universitas Qamarul Huda Badaruddin Bagu Author

DOI:

https://doi.org/10.55927/ngexj571

Keywords:

Wastewater, Anaerobic Biofilter WWTP, Descriptive, Parameters, Effectiveness

Abstract

Dompu General Hospital as one of the health facilities in Dompu Regency must be able to treat

wastewater properly. The hospital' s Wastewater Treatment Plant (WWTP) needs to be evaluated periodically to ensure that its performance is effective and efficient in processing wastewater. This research used is an experiment by conducting observational with a descriptive approach to evaluate the performance of the wastewater treatment plant system and to determine the effectiveness of the Biofilter Anaerobic Aerobic WWTP at Dompu General Hospital. The results of the quality test wastewater sample Biofilter Anaerobic Aerobic WWTP obtained from the parameters of TSS, BOD, COD, Oil and Water parameters and pH, show show figures within the standard for hospital wastewater quality. The results of laboratory tests for the 5 parameters are as follows: Total Suspended Solids (TSS) with a standard of 30 mg/L obtained a waste treatment result is 18.0 mg/L. Biological Oxygen Demand (BOD) test obtained a waste treatment process was 1.47 mg/L. The waste treatment results of Chemical Oxygen Demand (COD) was carried out, 28.9 mg/L. The waste treatment result of Oil & Water was carried out<1,00 mg/L

References

A study by Putri et al. (2020) found that WWTP efficiency is highly dependent on hydraulic residence time and the type of biological reactor used.

According to Saputra & Widodo (2019), routine maintenance and monitoring of effluent quality are critical factors in maintaining the effectiveness of hospital WWTPs.

Based on the results of a study by Nuraini et al. (2022), hospital management awareness of environmental regulations has increased along with the enforcement of environmental laws.

Handayani et al. (2021) emphasize the importance of periodically evaluating WWTP performance to minimize the impact of water pollution around hospitals.

Lestari, D. (2024). Membrane Technology Innovation for Hospital Wastewater Treatment. Journal of Environmental Engineering, 32(1), 21–29.

Martias, R. (2021). Descriptive Statistical Analysis in Engineering Research. Bandung: Alfabeta Press.

Nuraini, S., Sari, M., & Taufiq, R. (2022). Implementation of Hospital Wastewater Management Regulations in Indonesia. Journal of Law and Environment, 18(3), 301–312.

Putri, A. D., Susanto, B., & Kurniawan, H. (2020). Analysis of Hospital Wastewater Treatment Plant System Efficiency Based on BOD, COD, and TSS Parameters. Journal of Civil and Environmental Engineering, 25(1), 45–53.

Rahmadani & Yusuf (2023) reported that the implementation of an aerated biofilter-based wastewater treatment plant (WWTP) system can reduce BOD levels by up to 90%.

Rahmadani, F., & Yusuf, M. (2023). Application of Aerated Biofilters in Hospital Wastewater Treatment. Journal of Technology and Water, 12(4), 87–95.

Regulation of the Minister of Environment of the Republic of Indonesia Number 5 of 2014 establishes quality standards for domestic wastewater, including hospital wastewater.

Regulation of the Minister of Environment of the Republic of Indonesia Number 5 of 2014 concerning Wastewater Quality Standards. Jakarta.

Research by Rahayu & Sitorus (2018) shows that suboptimal hospital wastewater treatment plant (WWTP) systems can increase BOD and COD levels in the surrounding environment.

Published